Component parts for electric cookers
Showing 1–10 of 16 results
-
2-poles temperature controller: when set temperature is reached, controller automatically breaks electric circuit, when temperature is lowered — circuit is again connected, thereby it helps to keep temperature of controlled environment in constant narrow range.
Fields of application:
— Accumulation boilers, water heaters
— Washing machines
— Electric ovens, kitchen stoves
— Refrigerators
Switching current: up to 25A;
Control range: up to 355 C;
Number of operations: up to 100 000 cycles.
Capillary length: 250-2000 (2500)
Sensing element: CU: Ø5, Ø6, Ø6,5, Ø8, inox: Ø3, Ø4, Ø6
Such thermostat can also be used for regulating even with two different temperature settings!
-
3-poles temperature controller: when set temperature is reached, controller automatically breaks electric circuit, when temperature is lowered — circuit is again connected, thereby it helps to keep temperature of controlled environment in constant narrow range.
Fields of application:
— Accumulation boilers, water heaters
— Washing machines
— Electric ovens, kitchen stoves
— Refrigerators
Switching current: up to 25A;
Control range: up to 355 C;
Number of operations: up to 100 000 cycles.
Capillary length: 250-2000 (2500)
Sensing element: CU: Ø5, Ø6, Ø6,5, Ø8, inox: Ø3, Ø4, Ø6
Such thermostat can also be used for regulating even with three different temperature settings!
-
1-pole temperature controller: when set temperature is reached, controller automatically breaks electric circuit, when temperature is lowered — circuit is again connected, thereby it helps to keep temperature of controlled environment in constant narrow range.
Fields of application:
— Accumulation boilers, water heaters
— Washing machines
— Electric ovens, kitchen stoves
— Refrigerators
Switching current: up to 25A;
Control range: up to 355 C;
Number of operations: up to 100 000 cycles.
Capillary length: 250-2000 (2500)
Sensing element: CU: Ø5, Ø6, Ø6,5, Ø8, inox: Ø3, Ø4, Ø6
-
Our company can offer convection motors of the following characteristics:
Voltage: 100-240VAC
Frequency: 50 / 60HZ
Power: 5-100W
Insulation type: A / E / B / F / H
Noise: no more than 43Db (a)
Lifecycle: 5000-10000 hours
Core thickness: 8-40mm
Shaft diameter (mm): 2.5, 3.17, 4.0, 4.6, 5.0, 5.5, 6.0, 6.35
Variousfastening options. -
Electromechanical timers, offered by our company, are designed to control electrical appliances on a schedule. They are used to turn on/off lighting, etc. They are also used in other electrical devices during the daily or weekly cycle according to established program. There are mechanical, electrical, electromechanical timers. They differ from each other by dimensions, material, programming timing.
-
We offer glass-ceramic panels for induction hot plates of all kinds of sizes, any shape, as well as the number of burners. In addition, our glass-ceramic panels successfully passed testsof strength (Pan Drop Test). Heat resistance is up to 800C. Thermal conductivity λ (100°C) is about 1.7 W / (m ⋅ K)
-
Tubular electrical heaters of various sizes and capacities for household electric stoves.
Production according to customer drawings is possible. -
Cast iron hot plates for household electric stoves.
They successfully passed testing in the number of factories of the Russian Federation.
Diameter: 145mm and 180mm.
Power: 1000W to 2000W.t is possible to produce the whole hot plates as well as their components according to customer drawings.
Manufacturing of express hot plates is also possible.
-
Backlight lampswith ceramic holder, offered by our company, have the following characteristics: rated voltage — 250V; material — ceramic; Lamp power — 15W; Maximum temperature is up to 300C
-
More often it is used as a second stage of overheat protection when operational thermostat (themperature controller) does not disconnect the appliance when the set limit temperature is reached.
Limitative thermostat is actuated when limit temperature is reached — it leads to safety (emergency) opening of a circuit with the ability to turn it on manually after the fault handling.